berex b c if7 http: //www.berex.com 50-800 mhz internally matched if amplifier device features ? 40 dbm output ip3 at 70mhz, 14dbm/tone ? 27.0 db gain at 70mhz ? 21.0 dbm p1db at 70 mhz ? highly reliable ingap/gaas hbt technology ? patented over voltage protection circuit ? application: commercial wireless system target device performance (t a = 25 c) symbols parameters test co nditions min typ max unit gain 70mhz 140mhz 250mhz 500mhz 26.0 25.8 25. 24.9 27.0 26.8 26.7 25.9 db s11 70mhz 140mhz 250mhz 500mhz -30.8 -32.4 -29.4 -27.8 db s22 70mhz 140mhz 250mhz 500mhz -12.5 -12.5 -11.6 -8.6 db oip3 70mhz 140mhz 250mhz 500mhz 39.2 38.5 41.6 39.4 41.2 40.8 43.6 41.4 dbm p1db 70mhz 140mhz 250mhz 500mhz 20.3 20.8 20.7 19.2 21.3 21.8 21.7 20.2 dbm ic vc = 5.0v 85 95 105 ma vc 5.0 v dg/dt -0.003 c rth thermal resistance 50 c/w test conditions unless otherwise noted. 1. device performance is measured on berex evaluation board at 25 c, 50 ohm system. 2. oip3 is measured on an eval-board with two tones separated by 1 mhz. absolute maximum ratings parameter rating operating case temperature -40 to +85 c storage temperature -40 to +155 c supply voltage 6.0v max. device current 160ma input rf power 23dbm operation of this device above any of these parameters may result in permanent damage.
berex b c if7 http: //www.berex.com s-parameter test circuit chip attachment on pf083 31mil thick fr4 pcb generic pf083 evaluation board i-v characteristics application circui t: 50-800 mhz typical performance (vdevice = 5v, ic = 95 ma, ta = 25 c) freq mhz 70 140 250 500 s21 db 27.0 26.8 26.7 25.9 s11 db -30.8 -32.4 -29.4 -27.8 s22 db -12.5 -12.5 -11.6 -8.64 p1 dbm 21.3 21.8 21.7 20.2 oip3 dbm 41.2 40.8 43.6 41.4
berex b c if7 http: //www.berex.com schematic diagram bom tolerance c1 100nf *100pf 5% c2 100nf *100pf 5% c3 100pf 5% c4 1000pf 5% c5 10uf 20% l1 1uh *12nh 5% *application for rf bandwidth typical device data s-parameters (vc=5v, ic=95ma, t=25 c) if bandwidth application
berex b c if7 http: //www.berex.com s-parameters (vc=5v, ic=95ma, t=25 c) rf bandwidth application device performance p1db-gain p1 gain
berex b c if7 http: //www.berex.com oip3 s-parameter if bandwidth application (vc=5v, ic=95ma, t=25 c) freq [mhz] s11 [db] s11 [ang] s21 [db] s21 [ang] s12 [db] s12 [ang] s22 [db] s22 [ang] 50 -28.586 -106.642 27.021 176.006 -32.384 2.863 -12.028 22.476 150 -32.368 153.226 26.801 156.233 -31.914 -7.256 -12.467 -21.072 250 -29.436 103.952 26.672 135.931 -32.394 -13.069 -11.622 -41.718 350 -30.806 74.122 26.319 119.315 -30.952 -23.766 -10.324 -58.0256 450 -28025 57.612 26.102 102.363 -31.721 -36.896 -9.144 -72.792 550 -27.358 39.511 25.497 850.096 -31.882 -41.929 -8.246 -.58.005 650 -26.156 34.536 25.184 69.233 -31.562 -51.528 -7.420 -94.494 750 -28.741 16.783 24.699 56.366 -30.987 -55.955 -6.775 102.541 850 -28.388 26.499 23.915 36.370 -30.922 -65.779 -6.329 -113.462 * note : s-parameter includes 1 mil thick and 16-mil long au wire
berex b c if7 http: //www.berex.com rf bandwidth application (vc=5v, ic=95ma, t=25 c) freq [mhz] s11 [db] s11 [ang] s21 [db] s21 [ang] s12 [db] s12 [ang] s22 [db] s22 [ang] 500 -9.933 -62.036 26.655 140.862 -32.054 5.690 -6.741 95.975 600 -11.592 -69.083 27.012 114.561 -30.891 -10.142 -10.421 66.190 700 -12.970 -75.467 26.862 90.690 -30.452 -21.447 -14.326 28.112 800 -13.821 -81.199 26.486 70.988 -31.196 -39.664 -16.186 -31.310 900 -14.577 -89.643 26.003 51.737 -30.634 -47.501 -14.438 -74.036 1000 -15.849 -105.713 25.350 31.493 -29.676 -65.002 -11.274 -101.616 1100 -16.947 -116.273 25.174 17.566 -29.279 -73.650 -9.931 -115.456 1200 -18.847 -127.822 24.486 3.151 -29.542 -89.241 -8.173 -139.546 1300 -19.853 -145.186 23.909 -13.503 -29.542 -89.241 -8.173 -139.546 1400 -20.891 -168.828 23.719 -27.530 -28.848 -96.767 -7.982 -149.506 1500 -22.903 162.772 23.175 -42.466 -28.517 -107.766 -7.466 -156.464 * note : s-parameter includes 1 mil thick and 16-mil long au wire die outline notes: 1) die thickness 100um 2) bondpad metal thickness 2.8um 3) backside metal au, 5um 4) device is grounded through via holes
berex b c if7 http: //www.berex.com esd rating esd rating value test standard class 1c passes <2000v human body model (hbm) jedec standard jesd22-a114b nato cage code: notice berex corporation reserves the right to make changes of product specification or to discontinue product at any time without notice. 2 n 9 6 f
|